Motor Capacitor Sizing Calculator

Start cap. Run cap. Voltage rating. Enter HP and voltage — get the right capacitor sizes for your single-phase induction motor.

Motor Capacitor Sizing Calculator

Start cap, run cap & voltage rating for single-phase induction motors.

Motor type
Mains frequency
Recommended sizing
Start capacitor
5–7 µF
Run capacitor
0.4–0.9 µF
Capacitor voltage rating
330V
Start µF = 2652 × 0.5 ÷ 230 = 5.8
Motor power: 0.5 HP = 0.37 kW
Run cap (≈ 10%): 0.58 µF nominal

🔧 Microcopy. Start capacitors are electrolytic (non-polarized motor type), rated for intermittent use only — they cool between starts. Run capacitors are film or metallized polypropylene, rated for continuous duty. If your motor hums but won't start, the start cap is likely dead. If it starts but runs hot, the run cap has failed.

Why capacitors matter

Single-Phase Motors Cannot Start Without Capacitors

A single-phase induction motor has one main winding connected directly to mains — but a single phase cannot produce a rotating magnetic field on its own. The solution: add a second (start or auxiliary) winding shifted electrically by about 90° from the main winding. The phase shift comes from a capacitor placed in series with that second winding. Two magnetic fields, at different times, add up to a single rotating field — and the rotor turns.

Start capacitors deliver a large initial phase shift for starting torque, then drop out of the circuit once the motor reaches ~75% of synchronous speed (a centrifugal switch on the shaft handles this mechanically). Run capacitors stay in the auxiliary winding circuit continuously, providing a smaller permanent phase shift that improves running efficiency, power factor and torque at load.

A dead start capacitor = motor hums but does not start. A drifted run capacitor = motor starts but runs hot, draws high amps, and loses efficiency. Both symptoms are among the most common HVAC and appliance repair calls in the industry.

Single-phase induction motor with run capacitor and start capacitor connected to the start winding terminalsStart cap + run cap = rotating fieldPhoto: Unsplash
Reference

Single-Phase Induction Motor — Standard Start & Run Capacitor Sizes

These are industry-standard ranges at 50/60 Hz. Use the calculator above for your exact HP and voltage combination, or cross-reference here against a known motor.

Motor HPVoltageStart Cap Range (µF)Run Cap Range (µF)Capacitor Voltage Rating
1/6 HP120V70–105 µF2.5–3.5 µF250V
1/4 HP230V45–65 µF3–5 µF250V
1/2 HP230V80–100 µF5–7.5 µF250–330V
3/4 HP230V100–140 µF7–10 µF330V
1 HP230V140–180 µF8–12 µF330–370V
Test a motor cap in service with the dedicated HVAC under-load calculator — measure clamp-meter amps and terminal volts while the motor runs. For the physics behind the 2652 constant, visit the reactance tool. Browse every tool on the site at the calculators hub, or start at the Capacitor Calculator home page for code decoding and unit conversion.
Troubleshooting

Diagnosing Capacitor Failures in Single-Phase Motors

💡 Tip. Start caps carry 80–100 µF for most fractional horsepower motors; run caps are 1/10th that value or less. A dual capacitor marked '35 + 5' means the start section is 35 µF and the run section is 5 µF.

⚠️ Warning. Electrolytic start caps have a limited life (5 000–10 000 starts) and vent violently if they fail catastrophically. Film run caps last 15–25 years but can drift slowly out of tolerance. Always discharge caps through a 20 kΩ 5 W resistor before handling.

❌ Don't oversize. An oversized run capacitor over-excites the start winding, causing motor heat and premature winding failure. Stick to the range in the table above or your motor nameplate — don't "round up" for safety.

Questions About Motor Capacitors

How do I calculate motor start capacitor size?▼

Start capacitor µF = 2 652 × HP / V at 60 Hz (230V) or 5 304 × HP / V at 60 Hz (120V). These are HVAC industry constants. A 1/2 HP 230V motor: µF = 2652 × 0.5 / 230 ≈ 5.76 µF — practical start caps are 80–100 µF because start caps deliver energy, not phase shift. The constant alone gives only a guide.

What's the difference between a start cap and a run cap?▼

Start capacitors are non-polarized electrolytic, designed for intermittent duty only — they cool between starts. Their job is to deliver a burst of energy to the motor's start winding, creating starting torque. Run capacitors are film or metallized polypropylene, rated for continuous duty — they stay in the start winding circuit the whole time the motor runs, providing permanent phase shift for improved torque and efficiency.

What is a dual-value capacitor?▼

A dual-value capacitor combines a start cap and a run cap in one can — common in residential HVAC condensers. The can label reads '35 + 5' or '45 + 7.5': first number is the start section µF, second is the run section µF. They share a common terminal but are electrically independent sections.

Why use different constants for 120V vs 230V?▼

The 2652 and 5304 constants come from the reactance formula rearranged to solve for capacitance from current. C = I / (2πfV). A 230V motor draws roughly half the current of an equivalent 120V motor, so the constant doubles when voltage halves — 230V uses 2652, 120V uses 5304.

What voltage rating should my motor capacitor have?▼

Always use an equal-or-higher voltage rating. The motor operates at line voltage, but capacitors experience voltage up to 1.5× line voltage during startup transients. 230V line motors use 250–330V capacitors. 120V line motors typically use 250V caps. If in doubt, go higher — never lower.

What happens if I use the wrong capacitor size?▼

Three failure modes. Too small: motor hums but won't start, or starts slowly and overheats. Too large: motor starts fine but runs hot and draws high amps, damaging the start winding. Wrong voltage: cap fails prematurely or vents violently. Always match both µF and voltage to the motor nameplate.

How do I test a motor capacitor?▼

Use the HVAC under-load test — clamp the start winding lead, measure volts across the cap terminals while the motor runs, compute µF = 2652 × A ÷ V at 60 Hz. Graded: within ±5% = good, 5–10% off = marginal, beyond ±10% = replace. The dedicated under-load calculator on this site runs this formula for you.

My motor hums but won't start — is it the capacitor?▼

Probably. A dead start capacitor is the #1 cause of a motor that hums but does not start. Check it with a capacitance meter or the under-load test. If the cap reads good, investigate the start winding for open circuits, the centrifugal switch (if present), and the main winding for burned connections.

See Also

Capacitor Tools That Pair With Motor Sizing

Size the cap here, test it in service with the HVAC under-load tool, or calculate X꜀ at your mains frequency to understand the phase shift it produces.