RC Time Constant Calculator — τ = R × C
Every RC circuit in electronics follows τ = R × C. Get τ, 5τ, fc and charge/discharge curves instantly.
RC Time Constant Calculator
τ = R × C — charge/discharge curve values, 5τ, and cutoff frequency.
⏱️ Microcopy. 5τ is the industry convention for "fully settled" — after 5 time constants the capacitor is within 0.7% of its final value. This is the number datasheets mean when they say "settling time". For constant-current charging (e.g., from a current source), charge time t = C × V / I, not RC. Toggle to CC mode if your supply is current-limited.
One Number Describes the Whole Curve
If you connect a capacitor to a supply through a resistor, the voltage across the capacitor climbs along an exponential curve: V(t) = V₀ × (1 − e^(−t/τ)). The entire curve — every point on it — is controlled by a single number: τ (tau), which equals R × C. Plug R in ohms and C in farads, and τ comes out in seconds. That is not an approximation; that is a mathematical identity.
The time constant is the time it takes the capacitor to reach exactly 63.2% of the supply voltage. That number comes straight out of the equation: 1 − e⁻¹ = 0.632 12. It is the e-folding time — the period of exponential growth — and it appears in countless other physical systems: diffusion, heat flow, radioactive decay, and population growth.
If τ is 100 ms, then after 100 ms the capacitor sits at 63.2% of V₀. After 200 ms it reaches 86.5%. After 500 ms — five time constants — it hits 99.3%. Engineers stop counting there. One more τ gets you to 99.75%, and mathematically the capacitor never truly reaches 100%.
Standard RC Filter Corner Frequency vs Time Constant
τ is the time domain constant. The same RC pair in frequency domain gives a corner frequency fc = 1/(2πRC). The two numbers are different faces of the same circuit. Every row below is computed from both formulas — try plugging R and C into the calculator above to verify each number.
| R Value | C Value | τ (RC) Time | 5τ Settling Time | Cutoff Frequency fc = 1/(2πRC) |
|---|---|---|---|---|
| 1 kΩ | 100 nF | 100 µs | 500 µs | 1 591 Hz |
| 10 kΩ | 10 µF | 100 ms | 500 ms | 1.59 Hz |
| 100 kΩ | 1 µF | 100 ms | 500 ms | 1.59 Hz |
| 10 MΩ | 1 nF | 10 ms | 50 ms | 15.9 Hz |
| 4.7 kΩ | 100 nF | 470 µs | 2.35 ms | 339 Hz |
| 22 kΩ | 220 nF | 4.84 ms | 24.2 ms | 32.9 Hz |
The 63.2% Rule, One Tau at a Time
Both charging and discharging follow the same exponential decay — they are just mirror images. The charging voltage climbs V(t) = V₀(1 − e^(−t/τ)); the discharging voltage falls V(t) = V₀e^(−t/τ). The table below shows both sides at every integer multiple of τ.
💡 Tip. Pick τ = 1/(2π×f_cutoff) as your design constraint. If you need an RC low-pass with fc = 1 kHz, τ = 0.159 ms, so any R×C product of 1.59 × 10⁻⁷ works — R = 1.59 kΩ + C = 100 nF, or R = 15.9 kΩ + C = 10 nF.
⚠️ Warning. Do not confuse RC time constant with the period T of an RC oscillator. For a 555 astable multivibrator, the high time is ≈ 0.693 × (R_A + 2R_B) × C — a different factor entirely. The τ = RC formula applies to simple series RC networks being charged or discharged by a voltage source.
❌ Don't assume. For constant-current charging from a current source — common in LED drivers and battery chargers — charge time is t = C × V / I, not RC. A 100 µF cap at 1A takes 1.2 ms to reach 12V — orders of magnitude faster than the resistor-limited RC case. If your supply is current-limited, τ = RC does not apply.
| Elapsed | Charged | Discharged | Energy remaining (charge) |
|---|---|---|---|
| τ | 63.2% | 36.8% | 13.5% |
| 2τ | 86.5% | 13.5% | 1.8% |
| 3τ | 95% | 5% | 0.2% |
| 4τ | 98.2% | 1.8% | 0% |
| 5τ | 99.3% | 0.7% | 0% |
τ = RC Comes From Kirchhoff's Voltage Law
If you place a resistor R in series with a capacitor C and connect a voltage source V₀, Kirchhoff's voltage law demands that the sum of voltages around the loop equals zero. The voltage across the resistor is V_R = I × R, and the voltage across the capacitor is V_C = Q / C, where Q is charge. Since current I = dQ/dt, the KVL equation becomes:
V₀ = I·R + Q/C
V₀ = R·dQ/dt + Q/C
→ dQ/dt = (V₀ − Q/C) / R
Solution: Q(t) = C·V₀·(1 − e^(−t/(RC)))
The solution of that first-order ODE is the exponential curve we have been talking about — and the time constant τ = RC pops out of the exponent automatically. It is not a convention or an approximation; it is the natural time scale of the differential equation that describes every RC circuit.
Questions About RC Time Constants
What is the RC time constant formula?▼
τ (tau) = R × C exactly, with R in ohms and C in farads producing τ in seconds. If R is 10 kΩ and C is 10 µF, τ = 10 000 × 0.00001 = 0.1 seconds = 100 ms. The formula is clean dimensional analysis — ohms × farads = seconds by definition of the underlying SI units.
Why is 5τ the 'fully charged' convention?▼
At t = 5τ the capacitor voltage has reached V = V₀ × (1 − e⁻⁵) = V₀ × 0.99326 — within 0.7% of the supply voltage V₀. That residual 0.7% is below the tolerance of almost every capacitor on the market, so industry practice rounds it to 'charged'. One more τ (6τ) gets you to 99.75%, and infinite τ would get you to exactly 100%.
How does the time constant relate to cutoff frequency?▼
They are inversely linked through the same R and C: fc = 1/(2πRC) = 1/(2πτ). The cutoff frequency marks the point where a high-pass or low-pass RC filter attenuates the input by −3 dB (half-power). A 10 kΩ × 10 µF pair gives τ = 100 ms and fc = 1.59 Hz — meaning frequencies below 1.59 Hz get severely attenuated by this RC network.
Does the RC formula work for all capacitors?▼
The formula τ = RC is exact for ideal capacitors and nearly exact for real ones above audio frequencies. At very high frequencies, parasitic inductance (ESL) starts to matter; at very low frequencies, leakage current and dielectric absorption matter. For any practical circuit from DC up to several MHz, τ = RC is the right answer.
How do I calculate capacitor charge time for constant-current sources?▼
Constant-current charging follows a different formula: t = C × V / I, where I is the current in amperes. This is much faster than resistor-limited charging — a 100 µF cap charging to 12V at 1A takes only 1.2 ms, compared with 120 ms through a 120 Ω resistor. If your supply is current-limited rather than voltage-limited, toggle to CC mode in the calculator.
What is the difference between RC time constant and LC time constant?▼
RC circuits decay exponentially with τ = RC and no natural oscillation. LC circuits oscillate at ω = 1/√(LC) and decay with a time constant of L/R. If you build an RLC circuit with resistance in series with an LC pair, you get either an overdamped response (looks like RC), underdamped response (oscillations), or critically damped response (fastest non-oscillating step response).
How do I choose R and C for a specific time constant?▼
Work backwards from τ to a product R × C that equals it, then split the product according to practical constraints. If you need τ = 100 ms (0.1s), you could pick R = 1 kΩ and C = 100 µF, or R = 10 kΩ and C = 10 µF, or R = 100 kΩ and C = 1 µF. The larger the RC product for the same τ, the more energy the capacitor stores — pick the pair that fits your voltage rating and power-handling budget.
Is the RC time constant affected by series or parallel capacitors?▼
Yes. For RC pairs in parallel, τ remains R × C (parallel capacitance values add together, so a 10 µF + 10 µF pair through a 10 kΩ resistor has τ = 10 kΩ × 20 µF = 200 ms). For series capacitors, the effective capacitance is smaller (1/C_series = Σ1/C_i), so τ is shorter — two 10 µF caps in series through 10 kΩ gives C_series = 5 µF and τ = 50 ms.
See Also
τ lives alongside five other capacitor calculators — energy, charge, reactance, color code decoding, and motor sizing. Each covers a different variable in the capacitor equation family.
Related Resources
Capacitance Converter
Convert capacitance between pF, nF, µF, mF and F live, and t...
Series & Parallel Capacitors
Combine up to 12 capacitors in series or parallel with per-c...
Parallel Plate Capacitor
Compute capacitance from plate area, separation and dielectr...
HVAC Capacitor Under Load
Test an HVAC run capacitor under load: enter amps, volts and...
Capacitor Energy
Compute energy stored in any capacitor from E = ½CV² with li...
RC Time Constant
Get τ in seconds, ms, µs, ns from any R and C pair, plus the...
Capacitor Charge
Calculate stored charge Q = CV in C, mC, µC, nC, pC from cap...
Capacitive Reactance
Compute Xc in Ω/kΩ/MΩ from frequency and C, with parallel-R ...
Capacitor Color Code
Decode 3-band, 4-band and 5-band capacitor color codes to pF...
Motor Capacitor Sizing
Size start and run capacitors for split-phase, cap-start, ca...
Crystal Load Cap
Calculate C1 and C2 for a crystal oscillator: C = 2CL − Cstr...
Coupling & Bypass
Size AC coupling, input/output, emitter and cathode bypass c...
RC Filter Cap
Solve C = 1/(2πfR) for low-pass, high-pass, band-pass and no...
LC Resonance
Get f₀ = 1/(2π√LC) for parallel or series LC tanks, plus Q f...
Power Supply Cap
Size rectifier bulk, buck-converter output and hold-up capac...
Cap Voltage Divider
Split voltage across 2–4 series capacitors instantly: Vn = Q...